2) TECHNICAL DATA
Power supply
230Vac (50Hz)
Motor
1400/g/min
Absorbed current
1,1 A
Thrust
5000 N (~500Kg)
Max pressure
33 bar
P
rotection rating
IP55
N° cons.ve manoeuv.
Intense use
Pump
a lobi
Ram shaft diameter
Ø 20mm
Noise level
< 70 dB (a)
Overload cut-out
150°C
Operating temp.
-20°C/+50°C
Condenser
10µF
Oil
HYDRO OIL
3) MODEL SIZING
MODEL
Door leaf weight
(kg)
Door leaf width
(m)
Stroke length
(mm)
Pump delivery
(l/min)
Ram speed
(cm/s)
Type of lock
HD.35
500
3,5
270
1
1,3
¢
HD.35 C
500
3,5*
270
1
1,3
v
HD.35 AC
500
3,5*
270
1
1,3
vw
HD.45
500
4,5
270
0,75
1
¢
HD.50
500
5
390
0,75
1
¢
HD.50 AC
500
5*
390
0,75
1
vw
LEGEND
DESCRIPTION
¢
Reversible (Requires electric lock)
v
One-way opening - Reversible closing (Requires electric lock)
w
Reversible opening - One-way closing
vw
One-way
4) PRELIMINARY CHECKS
For the gate automation to work properly, the actual gate must have the following characteristics:
- it must be robust and rigid.
- the hinges must have only limited play and provide smooth and gentle gate movements.
- the whole height of the wings must be in contact when closed.
5) OVERALL DIMENSIONS (FIG.1-2)
*N.B. For wings longer than 1.8m an electric lock is recommended even on one-way models. Slowdown in the closing stroke is standard on
all models.
6) GATE STOPS
If they are not already provided, install gate stops on the opening and closing stroke limits (Fig.3) regardless of the type of operator being installed.
The closed stop in particular is indispensable given the special characteristics of hydraulic operators. See “maintain stop” function in the instructions
for the control unit.
7) INSTALLING THE AUTOMATION SYSTEM
1 Establish the height of the automation from the ground (preferably as close to the centre of the wing as possible and along a solid cross rail).
Remember that under the operator there is a vent hole and in certain conditions (e.g. rain or snow) it may draw liquid into the automation. For this
reason it is best not to install the operator too close to the ground.
2 Weld or otherwise anchor plate P in place, see installation distances (Fig.2) and the installation diagram (Fig.5):
- remove screws V and cover C
- insert pin P in bracket P as in the figure
- lock everything in place by washer R and self-locking nut D
-
remove the vent plug VS with its gasket RS
. (see note “Vent plug”)
Observe the distances given in the tables at fig. 2, correcting the length of the plate if necessary. In some cases a recess may have to be made in
the post.
It is essential that the installation distances are respected for the operator to work correctly.
With reference to the installation tables note that:
For the wing to open 90°:
A+B must be equal to the operator stroke
For the wing to open more than 90°:
A+B must be less than the operator stroke.
Keep the length differences within 40mm. Over this difference the wing movement becomes uneven. When reducing lengths A and B , increase the
wing speed.
Comply with all statutory regulations.
3 Release the operator (see section “manual gate operation”)
4 Slide out the ram shaft completely and then slide back in by approx. 10 mm. Lock the operator in place (fig.4).
Always leave a safety overrun of 10 mm in both the closing and opening strokes. The stroke length given in the technical data and installation tables