5
PANEL PRO
right angle so that the right hand can reach the keypad, and the left hand can
reach the router.
Electrical Service:
The Panel Pro should be on its own 20 amp 120vac circuit. If there are any other loads
on the circuit, they must be light loads and not heavy loads like an air compressor, air
conditioner or other motor.
Do not use extension cords or power strips
.
The circuit absolutely MUST have a proper ground! The computer running the panel
Pro may be on the same circuit. It is just essential that there is the same ground on
both the Panel Pro and the computer.
The Milwaukee router draws around 12 amps at turn on. If extension cords are used or
other loads on the circuit cause the voltage to dip, it may cause the processor in the
controller to lock up or work erratically.
Nearby running water is highly recommended to wash chips off of hands and finished
parts, and to replenish the coolant. A laundry tub works great for this purpose.
Hardware setup:
1.
After removing the crate top, remove the 2x2s in the top ends of the crate.