Operating
- 3.40 -
SMART 3000TW
PX Programming Level
CONTROL
#
#
#
#
**PX**
The PX level allows you to program the following functions:
!
START frequency (global to all sensors)
!
STOP frequency (global to all sensors)
!
H_SPEED function enabled/disabled
While the system is in control condition, press and hold for 3 seconds
When the display shows **P1**, press again and hold for 3 seconds
.
This screen indicates that the PX programming level has been activated.
Press
to select the first programmable parameter of PX level
(F_START).
F_START: START Frequency
This function allows you to program the START frequency applied to all sensors
connected to
SMART 3000TW
terminal.
The START frequency is the minimum yarn image variation frequency above
which the sensor indicates the yarn running condition
(green LED on).
For more details please refers to “Settings that affect the sensor detection
features” paragraph.
Allowed values [001 ÷ 010]; Default [005].
: increases 0nn
: decreases 0nn
Press
to communicate the set value to all the sensors connected to each
Board and move to the next function
(F_STOP).
If one of the sensors does not reply correctly, on ERROR Dxxx B0n on message
appears.
In this case, press RESET and refer to chapter 4 “Troubleshooting”.
Summary of Contents for IS3
Page 1: ...SMART 3000TW IS3 YARN CONTROL SYSTEM Operating Manual ENGLISH ...
Page 14: ...Technical Data and Installation 2 6 SMART 3000TW Page intentionally left blank ...
Page 35: ...Operating SMART 3000TW 3 21 Summary Diagram of SMART 3000TW Programming Configuration Menu ...
Page 66: ...Appendix A Quick Reference A 2 SMART 3000TW Symbols Key ...
Page 67: ...Appendix A Quick Reference SMART 3000TW A 3 Symbols Key ...
Page 68: ...Appendix A Quick Reference A 4 SMART 3000TW Symbols Key ...
Page 69: ...Appendix A Quick Reference SMART 3000TW A 5 Symbols Key ...
Page 70: ...Appendix A Quick Reference A 6 SMART 3000TW Page intentionally left blank ...