Operating
SMART 3000TW
- 3.25 -
NUMBER LAMPS: Numbering of LAMP 485 Devices (Optional)
When
all
sensors connected to
all
Boards have been numbered, the NUMBER
LAMPS screen appears
(providing that the Bars Priority is active in menu P2).
Press
to start the LAMP 485 devices numbering.
Press
to continue without performing the devices numbering.
Press
to number the bars connected to LAMP 485 devices 01.
Set the number of LAMP 485 devices connected to Board 01.
Allowed values: [001 ÷ 030].
Press
to increase nnn
Press
to decrease nnn
When nnn corresponds to the number of Devices actually connected to Board 01,
press
to start the numbering sequence.
This screen indicates that the phase of automatic LAMP 485 devices numbering is
starting:
nnn
= shows the total amount of devices to be numbered
mmm
= shows the number of the first device
(and subsequently the next one)
to be
numbered.
!
Check that the LAMP 485 devices on top of all bars is flashing green, to
indicate the “Bar ready to be numbered” condition.
Press the button of LAMP 485 devices to which you wish to assign the number
shown by mmm and check that:
a)
The signalling lamp changes from flashing green to steady green
b)
The number mmm is increased by 1 unit.
Repeat the operation on all LAMP 485 devices connected to the Board 01.
When the numbering of all devices connected to Board 01 is completed, the
LAMPS BOARD 02 screen will appear.
Repeat the procedure described for numbering of Board 01, until you complete the
numbering of all devices.
When the numbering phase is complete, the system will automatically move to the
next function
(KEY_COD).
Summary of Contents for IS3
Page 1: ...SMART 3000TW IS3 YARN CONTROL SYSTEM Operating Manual ENGLISH ...
Page 14: ...Technical Data and Installation 2 6 SMART 3000TW Page intentionally left blank ...
Page 35: ...Operating SMART 3000TW 3 21 Summary Diagram of SMART 3000TW Programming Configuration Menu ...
Page 66: ...Appendix A Quick Reference A 2 SMART 3000TW Symbols Key ...
Page 67: ...Appendix A Quick Reference SMART 3000TW A 3 Symbols Key ...
Page 68: ...Appendix A Quick Reference A 4 SMART 3000TW Symbols Key ...
Page 69: ...Appendix A Quick Reference SMART 3000TW A 5 Symbols Key ...
Page 70: ...Appendix A Quick Reference A 6 SMART 3000TW Page intentionally left blank ...