![btsr IS3 Operating Manual Download Page 53](http://html.mh-extra.com/html/btsr/is3/is3_operating-manual_2825695053.webp)
Operating
SMART 3000TW
- 3.39 -
This test does not provide any diagnostic message on SMART display.
You will have to simply select the number of desired Bar (LPS nnn), using the
button, and check that the Red light of all LAMP 485 devices identified by
nnn is blinking
(Devices nnn connected to Board01, Devices nnn connected to
Board 02 … Devices nnn connected to Board 08).
!
If the Red light of a LAMP 485 device that should respond to nnn number,
actually does not respond, it means that either the Device driving Board is
faulty, the lamp is defective on the Devices numbering procedure was not
correct (see NUMBER LAMPS within the P1 menu level).
Press
to select the next device and check that the Red Light of Devices
connected to all the Boards are blinking.
Repeat the test for all connected Boards.
Press
to move to the next function
(LPS_B01).
LPS_B01: Testing the Efficiency Rate over the
Communications Line between the SMART 3000TW
terminal and all LAMP 485 Devices connected to the
various Boards
This function allows to check the perfect operation of the communications line
between the
SMART 3000TW
terminal and LAMP 485 devices connected to the
individual Boards.
It is suggested to run this check during the first testing phase
(immediately after
installation)
and each time random problems occur in the system operation, which
may have been caused by inefficient communications between the sensor and the
terminal
(for example: ERROR Dxxx).
From this moment on, the system communicates repeatedly with all connected
sensors. The test running status is signalled by the flashing red LED embedded in
the ENTER button. If there are no communication errors detected, the display
shows the message LPS_B01 000/000. If communication errors are detected, the
display shows the message LPS_B01 XXX/YYY, where the XXX indicates the
total number of failed attempts and YYY indicates the total number of sensors
where some problems occurred.
Press
to check the communication with Board 02 and so on for all
connected Boards.
Press
to leave the function and return to **TEST** menu.
At this point either press
to select a new menu, or press
to resume the
control condition
(CONTROL nnnn).
Summary of Contents for IS3
Page 1: ...SMART 3000TW IS3 YARN CONTROL SYSTEM Operating Manual ENGLISH ...
Page 14: ...Technical Data and Installation 2 6 SMART 3000TW Page intentionally left blank ...
Page 35: ...Operating SMART 3000TW 3 21 Summary Diagram of SMART 3000TW Programming Configuration Menu ...
Page 66: ...Appendix A Quick Reference A 2 SMART 3000TW Symbols Key ...
Page 67: ...Appendix A Quick Reference SMART 3000TW A 3 Symbols Key ...
Page 68: ...Appendix A Quick Reference A 4 SMART 3000TW Symbols Key ...
Page 69: ...Appendix A Quick Reference SMART 3000TW A 5 Symbols Key ...
Page 70: ...Appendix A Quick Reference A 6 SMART 3000TW Page intentionally left blank ...