BTR Controls, Inc.
PROGRAMMING
DG-Mini V7 Rev. C Standard HW manual V 1.0.2
33
L
IMIT
S
ETUP
The DG-Mini allows for several programmable
door positions. The connected encoder is
used to determine the door position.
Common door positions are shown in the
example to the right. Additionally, depending
on the encoder type it may be necessary to
have a reference switch input so that the
controller can determine a door’s position
after power up.
Rolling door positions example:
Breakaway
Fully Open
Pre open
Part open 1
Part open 2
Photoeye OFF
Safety edge OFF
Pre closed
Fully closed
Position
Description
Breakaway
This is a position used on some door types to reset a
breakaway condition.
Fully Open
Highest position the door will travel to under normal
operation
Pre Open
The position at which the controller starts to slow
down an opening door
Part 1
A position below Fully Open, usually used for man or
low height vehicle traffic.
Part 2
A position lower than Part 1, also usually used for man
or low height vehicle traffic.
Photoeye OFF
The position below which the controller ignores
activation of the photoeye input
Safety edge Off
The position below which the controller ignores
activation of the safety edge
Pre Closed
The position at which the controller starts to slow
down a closing door
Closed
Lowest position the door will travel to under normal
operation
Summary of Contents for DG-Mini
Page 1: ...DG Mini Rev C Standard HW manual V 1 0 0 1 DG Mini Universal Door Control ...
Page 25: ...BTR Controls Inc MENU NAVIGATION DG Mini V7 Rev C Standard HW manual V 1 0 2 25 MENU TREE ...
Page 65: ...BTR Controls Inc SPECIFICATIONS DG Mini V7 Rev C Standard HW manual V 1 0 2 65 DG Mini 1500G ...
Page 68: ...BTR Controls Inc APPENDIX DG Mini V7 Rev C Standard HW manual V 1 0 2 68 APPENDIX ...
Page 69: ...BTR Controls Inc APPENDIX DG Mini V7 Rev C Standard HW manual V 1 0 2 69 ...
Page 71: ...BTR Controls Inc APPENDIX DG Mini V7 Rev C Standard HW manual V 1 0 2 71 ...