BTR Controls, Inc.
PROGRAMMING
DG-Mini V7 Rev. C Standard HW manual V 1.0.2
55
S
EYWAVE
H
OST
Description:
This submenu is used to enable the Internal Seywave system, pair remotes and sensors and to adjust operational
settings.
It contains additional submenus for adjusting a sensor’s impact level for breakaway detection and to expand the
time window for which the sensor is looking for motion when a door starts to close.
Refer to the documentation supplied with the SeyWave device for additional details.
Enable
Submenu to enable or disable the internal Seywave Host.
Pairing
Submenu to connect (pair) a SeyWave Wireless remote or sensor to the
DG-Mini.
Entering this menu will place the DG-Mini into pairing mode where it
attempts to pair with a remote device. If successful, the paired device will
be displayed on the screen. Otherwise “No Remotes Found” will be
displayed.
Once a device has been paired it will start functioning immediately
without any further configuration.
Clear All
This submenu is used to disconnect all previously paired SeyWave devices
from the DG-Mini.
Performing this step will require all SeyWave devices to be Paired again.
Performing this step will also cause the Internal SeyWave to automatically
change the communication settings which include the channel and
address used by the system. These settings are not user configurable.
Perform a Clear All if performance issues are encountered.
Information
This submenu displays information about the software version.
Fast Sensor
This Submenu is used to enable or disable the Fast Sensor mode on a
paired SeyWave Molded Door Sensor.
Consult factory for usage details.
Impact Adjust
This submenu is used to adjust the Seywave Molded Sensor’s breakaway
impact detection level. The detection level can be set based on presets or
manually adjusted.
Note: The detection level value is a relative scale with zero being the most
sensitive and a larger number represents a more severe impact before the
breakaway fault is generated.
Motion Adjust
This submenu is used to adjust the maximum amount of time the DG-Mini
will wait for a valid motion check message from a SeyWave Molded
Sensor during a closing cycle.
WARNING!
Disabling this check is not recommended.
Additional entrapment protection will be required
if disabled.
Summary of Contents for DG-Mini
Page 1: ...DG Mini Rev C Standard HW manual V 1 0 0 1 DG Mini Universal Door Control ...
Page 25: ...BTR Controls Inc MENU NAVIGATION DG Mini V7 Rev C Standard HW manual V 1 0 2 25 MENU TREE ...
Page 65: ...BTR Controls Inc SPECIFICATIONS DG Mini V7 Rev C Standard HW manual V 1 0 2 65 DG Mini 1500G ...
Page 68: ...BTR Controls Inc APPENDIX DG Mini V7 Rev C Standard HW manual V 1 0 2 68 APPENDIX ...
Page 69: ...BTR Controls Inc APPENDIX DG Mini V7 Rev C Standard HW manual V 1 0 2 69 ...
Page 71: ...BTR Controls Inc APPENDIX DG Mini V7 Rev C Standard HW manual V 1 0 2 71 ...