BTR Controls, Inc.
PROGRAMMING
DG-Mini V7 Rev. C Standard HW manual V 1.0.2
53
DG-Xnet
This menu is used to configure the DG-Mini when the DG-Xnet is installed.
Note: The DG-Xnet is an optional feature requiring a special hardware module connected that is connected to the
controller’s RS485 port. The DG-Mini must detect this module during startup; therefore ensure required
connections are made prior to startup. Refer to DG-Xnet documentation for further details.
DG-X
NET
M
ENU
Submenu
Description:
Enable
Enable
Submenu to enable or disable DG–Xnet operation
Disable
Discover
Used to find other DG- Xnet devices in range.
Connect
Submenu to enable communication between other DG-Xnet devices.
X-Lock
Submenu to enable a wireless airlock between and up to five other
DG-Xnet devices.
Clear all
Used to disconnect all previously connected DG-Xnet devices from the
DG-Mini. A reconfiguration of the DG-Xnet will be required.
Settings
Channel
Used to set the communication channel
for the DG-Xnet.
NOTE
Network ID
Used to set the Network ID for the DG-
Xnet.
These settings must match
all other DG-Xnet devices
that are to be networked
Summary of Contents for DG-Mini
Page 1: ...DG Mini Rev C Standard HW manual V 1 0 0 1 DG Mini Universal Door Control ...
Page 25: ...BTR Controls Inc MENU NAVIGATION DG Mini V7 Rev C Standard HW manual V 1 0 2 25 MENU TREE ...
Page 65: ...BTR Controls Inc SPECIFICATIONS DG Mini V7 Rev C Standard HW manual V 1 0 2 65 DG Mini 1500G ...
Page 68: ...BTR Controls Inc APPENDIX DG Mini V7 Rev C Standard HW manual V 1 0 2 68 APPENDIX ...
Page 69: ...BTR Controls Inc APPENDIX DG Mini V7 Rev C Standard HW manual V 1 0 2 69 ...
Page 71: ...BTR Controls Inc APPENDIX DG Mini V7 Rev C Standard HW manual V 1 0 2 71 ...