BTR Controls, Inc.
PROGRAMMING
DG-Mini V7 Rev. C Standard HW manual V 1.0.2
29
Express Menu
The Express menu provides a quick method to edit commonly used parameters.
It is entered by pressing
UP
button while the controller is in the IDLE screen. It navigated using the standard
UP
,
DOWN
and
MENU/ENTER
buttons described earlier.
E
XPRESS
M
ENU
Menu and Submenu
Description:
Display
Readout
Normal
Displays the standard Idle screen.
Motor Current
Displays actual motor current measured by the controller.
DC Link
Displays the internal DC Link voltage.
Position
Displays the current position in Encoder Counts.
Measured
Frequency
Displays the measured frequency calculated from a
compatible encoder.
Output Frequency
Displays the frequency output to the motor.
Auto 1 Timer
Shortcut to adjust the Auto 1 Timer.
Man 1 Timer
Shortcut to adjust the Manual 1 Timer.
DTO Timer
Shortcut to adjust the Delay To Open Timer.
DTC Timer
Shortcut to adjust the Delay To Close Timer.
Open Alarm
Shortcut to adjust the Open Alarm Timer.
Run Timer
Shortcut to adjust the Run Timer.
Emergency Jog
While in this menu the controller will operate jog mode.
WARNING
ANY CONNECTED SAFETY
INPUTS WILL BE IGNORED TO
ALLOW UNRESTRICTED
MOVEMENT OF THE DOOR.
Reset
Shortcut to reset the controller.
Summary of Contents for DG-Mini
Page 1: ...DG Mini Rev C Standard HW manual V 1 0 0 1 DG Mini Universal Door Control ...
Page 25: ...BTR Controls Inc MENU NAVIGATION DG Mini V7 Rev C Standard HW manual V 1 0 2 25 MENU TREE ...
Page 65: ...BTR Controls Inc SPECIFICATIONS DG Mini V7 Rev C Standard HW manual V 1 0 2 65 DG Mini 1500G ...
Page 68: ...BTR Controls Inc APPENDIX DG Mini V7 Rev C Standard HW manual V 1 0 2 68 APPENDIX ...
Page 69: ...BTR Controls Inc APPENDIX DG Mini V7 Rev C Standard HW manual V 1 0 2 69 ...