REQUENCIES
This menu is used to adjust the various speeds used by the DG-Mini during operation of the door.
Since the speed of the motor is directly proportional to the frequency of the voltage applied to it, the DG-Mini is able
to control the door’s speed by controlling both the voltage and frequency during door movement.
F
REQUENCY
M
ENU
Event:
Description:
Open
This frequency sets the maximum speed between the closed and pre-open
positions.
Pre Open
This frequency sets the maximum speed between the pre-open and the
Fully Open positions.
Close
This frequency sets the maximum speed between the open and pre-closed
positions.
Pre Close
This frequency sets the maximum speed between the between the pre-
closed and the Fully Closed positions.
Dead man
This frequency sets the maximum speed when operating under a
constant-pressure mode or during a reference run.
Minimum
This frequency set the minimum speed of the motor.
The DG-Mini will apply DC-Brake current when the motor’s speed is less
than this value.
Illistration of door speeds during a door opening and closing cycle.
Door position is on X-axis and door speed on is on Y-axis. (Note: Speeds are always positive;
Closing speeds shown as ‘negative” only for clairty )
Summary of Contents for DG-Mini
Page 1: ...DG Mini Rev C Standard HW manual V 1 0 0 1 DG Mini Universal Door Control ...
Page 25: ...BTR Controls Inc MENU NAVIGATION DG Mini V7 Rev C Standard HW manual V 1 0 2 25 MENU TREE ...
Page 65: ...BTR Controls Inc SPECIFICATIONS DG Mini V7 Rev C Standard HW manual V 1 0 2 65 DG Mini 1500G ...
Page 68: ...BTR Controls Inc APPENDIX DG Mini V7 Rev C Standard HW manual V 1 0 2 68 APPENDIX ...
Page 69: ...BTR Controls Inc APPENDIX DG Mini V7 Rev C Standard HW manual V 1 0 2 69 ...
Page 71: ...BTR Controls Inc APPENDIX DG Mini V7 Rev C Standard HW manual V 1 0 2 71 ...