BTR Controls, Inc.
BASIC
WIRING
DG-Mini V7 Rev. C Standard HW manual V 1.0.2
16
S
AFETY EDGES
The DG-Mini supports multiple types of Safety
Edges connections. Connection details and
programming details are illustrated below.
C
ONDUCTIVE WITH RESISTOR
Connect the safety edge to terminals 1 and 2. The Safety Edge can be either a normally-open or normally-closed contact
with termination resistor. The value of the required termination resistor and contact type must match the setting in the
DG-Mini. If no safety edge is connected, the door will only operate in jog mode.
Note
Set the type of connected safety edge using
the menu:
System Config-
Safety Edges
Refer to the Safety Edge menu description
for additional information.
WARNING
It is essential that a UL 325 compliant
entrapment protection device be used in
conjunction with the DG-Mini.
If the entrapment proection is a safety
edge, only use the dedicated safety edge
inputs on terminals 1 and 27.
Note: Normally-Open type safety edge shown