Synergy Technician's Software Reference Page 5
●
IP
: The IP Address of the Synergy Pretreater.
● Firefly IP
: The IP Address of the Firefly that the
Synergy Pretreater is connected to.
●
Device ID
: The Device ID of the Pretreater.
● Firefly Port
: The communications port for the
Firefly.
There are also buttons for sending commands to the firefly
●
Target Lane
: Sets the target lane to be used when
sending commands from this screen.
●
Program
: Program code to send when pressing
Send Program
●
Prewarm
: Sends the command to the firefly to
initiate a prewarm if possible on the
target lane
.
●
Start Job
: Sends the command to start the firefly
job on the
target lane
.
●
Stop Job
: Sends the command to stop the firefly
job on the
target lane
.
●
Send Program
: Sends the set
Program
to the Fire-
fly on the
target lane
.
Settings
This section describes all settings in the system, their func-
tion and purpose. Not all of these settings are intended to
be changed. After being configured during assembly, these
factory settings are flagged with a bold
-F
at the end. Other
settings are set-up at installation and may require adjust-
ment. These settings are flagged with a bold
-I
at the end.
●
Page 1
: Basic Settings for how the interface oper
-
ates with the Spray and Dry settings.
○
Load Returned Garment
: If enabled,
when the operator presses
Return
the
garment in the Spray Chamber will be
reloaded. In
Queue Mode,
this means the
garment is added to the top of the Queue.
○
Rotate Queue On Start
: If enabled, in
Queue Mode
when the operator presses
Start
the first garment is removed. Other
-
wise the Garment is removed when the belt
moves.
○
Spray Settings Format
: Determines how
the operator sets the
Carriage Speed.
■
Fixed Area Grams
: Set the car
-
riage speed by setting the Density
based on a fixed area. Entered in
grams.
■
Actual Grams
: Set the carriage
speed by setting the Density based
on the area selected. Entered in
grams.
■
Density
: Set the carriage speed
based on the nozzle that is selected
and the desired laydown density.
Entered in g/in
2
.
■
Speed
: Directly set the carriage
speed in in/s.
○
Fixed Area For Grams
: The value used
in Density calculations when using
Fixed
Area Grams
to set the
Carriage Speed
.
Value entered is in
2.
○
Auto Start Mode
: Determines when the
countdown timer starts for Auto-Start.
■
Start From Load
: The countdown
begins when the operator can load
again. Turns the countdown into a
load time.
■
Start From Start
: The countdown
begins the moment the start button
is pressed. The countdown holds
at 0 until the start button is en-
abled.
■
Start From Enabled
: The count
-
down begins the moment the start
button can be pressed.
○
Display Countdown
: If enabled, the num
-
ber next to the Start button will countdown,
otherwise the countdown is only be visible
on the load zone.
○
Image Halo Top/Bottom
: In Queue Mode,
when garments are scanned into the sys-
tem, this number is added to the top and
bottom of the given spray zone.
○
Image Halo Left/Right
: In Queue Mode,
when garments are scanned into the system
this number is added to the left and right of
the given spray zone.
○
Max Carriage Speed
-F
: The maximum
speed the carriage can move. Affects the
minimum spray density.
○
Min Carriage Speed -F
: The minimum
speed the carriage can move. Affects the
maximum spray density.
○
Max Carriage Passes -F
: The maximum
number of passes the system allows.
○
Max Spray Width -F
: The maximum
width the system sprays. Affects where the
dotted red lines appear on the
Load Zone
.
○
Min Spray Width -F
: The minimum width
the system sprays. Affects how small the
Spray Zone can be made.
○
Max Spray Length -F
: The maximum
length the system sprays (how far the car-
riage will move). Affects the length of the
Load Zone
.
○
Min Spray Length -F
: The minimum
length the system sprays. Affects how
small the Spray Zone can be made.
○
Nozzle Duty -F
: Affects how/if a nozzle
will “Click” during a spray by rapidly
cycling between open and closed.