Synergy Software Page 9
the line, and it is critical that this be run whenever
the Pretreat Source Jug for this line is replaced or
refilled.
This does not waste any fluid
. If this
sequence stops early then it is likely that a valve is
not closing that is supposed to.
▪
Fill Line With Water
: Fills the Pretreat Fluid
Line with water. This includes the Pretreat Mixing
Pump, Mixing Tank, and the current Spray Head
assigned to spray this fluid. It is advised that this
be used when the machine is to be left unused for
more than a day. After this operation is run the
system will keep track of the line being filled with
water and will not allow the operator to spray until
the line has been refilled with pretreat.
▪
Fill Line With Pretreat
: Fills the Pretreat Fluid
Line with mixed pretreat. This will automatically
prime and bleed all the pumps for this fluid line.
After this operation is performed the system should
be ready for spraying this fluid.
The
Spray Head Maintenance Card
allows the operator
to change which fluid comes out of that nozzle set, and
perform a number of maintenance operations. To change
the fluid that spray head uses press on the current fluid in
the top right corner of the maintenance card
,
and select the new fluid from the drop down.
Image 12
Image 12: Spray Head 1 Maintenance Card
• Spray Head Maintenance Operations
▪
Begin/Stop Flush
:
Configures the system to push
water through the nozzles associated with this
Spray Head, and begins spraying water. When
Stop is pressed the system reverts to the previous
spray configuration, however water remains in the
head.
▪
Begin/Stop Spray
: Configures the system to push
the default fluid through the nozzles associated
with this Spray Head, and begins spraying. When
Stop is pressed the system closes the nozzles.
▪
Remove Head
: Fills all Heads in the carriage with
Water and Depressurizes the carriage for removal.
This operation is the same regardless of which
Spray Head Maintenance Card
is it initiated on.
▪
De/Pressurize
: Depressurizes the head by
closing all source valves and opening all nozzles.
Repressurizes by closing all nozzles. This
operation is the same regardless of which
Spray
Head Maintenance Card
is it initiated on.
▪
Bleed Spray Pump
: Bleeds the pump used to
spray this head. This is done by closing all source
valves and opening a return valve to send mixed
pretreat back into the mixing tank that the spray
pump pulls from.
This does not waste any fluid
.
If this sequence stops early then it is likely that the
Spray Before Bleed
setting needs to be enabled.
Plumbing Configuration
At the bottom of the Maintenance Screen, beneath the
Maintenance Cards,
is the
Plumbing Configuration
Selector
. This will automatically apply and display a
configuration based on which lines are enabled and what
the default fluid is for each spray head. If the white box for
the Plumbing Configuration is empty, then that means the
system is not in a known configuration.
•
Known Plumbing Configurations
▪
Normal
: Both Pretreat Fluid Lines Enabled, Spray
Head 1 sprays Fluid 1, Spray Head 2 sprays Fluid
2.
▪
Line X Disabled
: Only that Pretreat Fluid Line is
Disabled, all Spray Heads are configured as they
would be in
Normal
(ie Line 1 Disabled).
▪
All Lines Disabled
: All Pretreat Fluid Lines are
disabled, All Spray Heads are configured as they
would be in
Normal
.
▪
Line X to Nozzle Set Y
:
All Pretreat Fluid Lines
except Line X are disabled, All Spray Heads are
configured to spray Water except for Spray Head Y,
which will spray Fluid X (ie Line 1 to Nozzle Set
2).