9. STANDARD ADJUSTMENTS
RH-9820
80
9-9. Adjusting the spreader installation positions
1. Loosen the set screw (4) and adjust spreader stopper L (5) so that the relative positions of the U-shaped part at the tip of
spreader L (1) and the lower thread guide hole (3) in the eye looper (2) are as shown in the illustration below.
2. Once adjustment is complete, tighten the set screw (4).
3. Loosen the set screw (8) and adjust the spreader stopper R (9) so that the top edge of the tip of spreader R (6) is aligned
with the top edge of the tip of looper R (7).
4. Once adjustment is complete, tighten the set screw (8).
NOTE:
Spreader L (1) and spreader R (6) should not protrude above the eye looper (2) or looper R (7) respectively. If they do,
skipped stitches or needle breakages may occur.
0494B