Printing Labels Using P-touch Template
69
6
Specifying the RS232C Serial Port Settings
6
If you are using a barcode scanner or other device with an RS-232C serial interface, you will need to set the
serial communications in the barcode scanner and the P-touch Label Printer to be the same in order to
operate reliably. You will also need the serial adapter (optional: PA-SCA-001).
Note
Refer to the barcode scanner programming reference manual before making these settings. We
recommend starting with the barcode scanner factory settings and change the communication settings in
the P-touch Label Printer because many barcode scanners are more difficult to program. The factory
communication settings for the P-touch Label Printer are shown below.
a
Click Communication Settings (B) shown in the previous step
"Specifying settings in the P-touch
Template Settings tool".
b
Change the settings as necessary, and then click [
Set
].
Note
Making the proper communication settings may require trying a few different settings so the
Communication Settings box does not close after clicking the [
Set
] button. After the proper settings have
been made, click [
Cancel
] or the red [
x
] in the upper right corner to close the Communication Settings box.
Baud rate
[
9600
] bps
Bit Length
[
8
] bits
Parity
[
None
]
Busy Control
[
DTR
]