2-75
Confidential
■
Error code C700
The memory is insufficient to expand the data of PC-Print.
Error code C800
The memory used to store secure print data exceeded the memory size for secure print data.
< User Check >
- Print the print data stored in the memory.
- Divide the print data and print it.
Out of Memory
Press Cancel
Print Data Full
Print Data is full. Press Cancel and delete the previously stored data.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.