2-108
Confidential
4.6 Troubleshooting for Control Panel Problems
4.6.1 Nothing is displayed on the LCD/LED
< User Check >
- Turn the power OFF/ON.
Step
Cause
Remedy
1
The version of the panel
firmware and the main
firmware do not match.
(Model with touch panel)
Install the latest panel firmware and main
firmware.
2
Connection failure of the key
PCB flat cable
(Model with touch panel)
Reconnect the key PCB flat cable.
3
Connection failure of the
panel PCB harness
(Model without touch panel)
Reconnect the panel PCB harness.
4
Connection failure of the LCD
flat cable
(Model without touch panel)
Reconnect the LCD flat cable.
5
Connection failure of the
low-voltage power supply
PCB harness
Reconnect the low-voltage power supply
PCB harness.
6
AC cord failure
Replace the AC cord.
7
Key PCB flat cable failure
(Model with touch panel)
Replace the key PCB flat cable.
8
Panel control PCB failure
(Model with touch panel)
Replace the panel control PCB ASSY.
9
LCD unit failure
(Model with touch panel)
Replace the LCD panel ASSY.
10
Key PCB failure
(Model with touch panel)
Replace the panel case ASSY.
11
Panel PCB failure
(Model without touch panel)
Replace the panel PCB ASSY.
12
LCD failure
(Model without touch panel)
Replace the LCD.
13
Low-voltage power supply
PCB failure
Replace the low-voltage power supply PCB
unit.
14
Main PCB failure
Replace the main PCB ASSY.