1.3.4 Operational check of LCD (Function code 12)
<Function>
This function is used to check that the LCD on the control panel is operating normally.
<Operating procedure>
Model without touch panel
(1) Press the
or
key to display “MAINTENANCE 12” on the LCD in the initial state of
the maintenance mode. Then, press the
OK
key.
(2) Each time you press the
Go
key, the LCD cycles through the displays as shown below.
(3) When the
Cancel
key is pressed, the machine returns to the initial state of the
maintenance mode, regardless of the display status.
<Display 1>
Backlight
LCD
Data LED
Error LED
: OFF
: Display of all dots
: Green ON
: Orange ON
<Display 2>
Backlight
LCD
Data LED
Error LED
: OFF
: Display of 16 dots in
2 lines
: Green ON
: Orange ON
<Display 3>
Backlight
LCD
Data LED
Error LED
: OFF
: Display of no dots
: Green ON
: Orange ON
<Display 4>
Backlight
LCD
Data LED
Error LED
: ON
: Display of no dots
: Green ON
: Orange ON
Fig. 5-3
Display 1
Display 2
Display 3
Display 4