Error code AE
This error does not usually occur in the normal use. The conceivable causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
Error, which cannot be specified, occurs.
■
Error code AF
The white tape cannot be detected.
■
Error code B0
Scanning flat cable connection failure.
* This error is indicated on the LCD in the maintenance mode.
Scan Unable AE
See Troubleshooting and routine maintenance chapter in User's Guide.
<User Check>
• Turn OFF the power switch, and turn it ON again after a while.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Scan Unable AF
See Troubleshooting and routine maintenance chapter in User's Guide.
Step
Cause
Remedy
1
White level data failure
Execute the
"Acquisition of white level data
.
2
Harness connection failure of
document scanner unit
Check the harness connection of the
document scanner unit and reconnect it.
3
Harness connection failure of FB
motor harness
Check the harness connection of the FB
motor harness and reconnect it.
4
Document scanner unit failure
Replace the document scanner unit.
5
Main PCB failure
Replace the main PCB ASSY.
Scanner Error B0
Step
Cause
Remedy
1
Incomplete insertion of the
harness of the document scanner
unit
Reconnect the harness for the document
scanner unit correctly.
2
Document scanner unit failure
Replace the document scanner unit.
3
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for DCP 7065DN
Page 21: ...CHAPTER 1 SPECIFICATIONS ...
Page 35: ...CHAPTER 2 ERROR INDICATION AND TROUBLESHOOTING ...
Page 44: ...2 7 Confidential ADF part Fig 2 5 Left Side Right Side Document feed path Face up ...
Page 142: ...CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 157: ...3 13 Confidential 4 New toner sensor PCB ASSY New toner sensor PCB ASSY Main PCB ASSY Guide ...
Page 169: ...3 25 Confidential 21 Hook switch PCB Guide Main PCB ASSY Hook switch PCB Side cover L ...
Page 252: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 264: ...CHAPTER 5 SERVICE FUNCTIONS ...
Page 271: ...5 5 Confidential Black and white scanning Fig 5 1 ...
Page 311: ...Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Page 313: ...6 1 Confidential 1 CIRCUIT DIAGRAMS High Voltage Power Supply PCB Circuit Diagram MURATA ...
Page 314: ...6 2 Confidential High Voltage Power Supply PCB Circuit Diagram Panasonic ...
Page 315: ...6 3 Confidential Low Voltage Power Supply PCB Circuit Diagram 115V EDPS 62AF A Delta ...
Page 316: ...6 4 Confidential Low Voltage Power Supply PCB Circuit Diagram 115V MPW3058 MURATA ...
Page 317: ...6 5 Confidential Low Voltage Power Supply PCB Circuit Diagram 230V EDPS 62BF A Delta ...
Page 318: ...6 6 Confidential Low Voltage Power Supply PCB Circuit Diagram 230V MPW3059 MURATA ...
Page 319: ...6 7 Confidential NCU PCB Circuit Diagram U S A Canada ...
Page 320: ...6 8 Confidential NCU PCB Circuit Diagram Europe Oceania ...
Page 321: ...6 9 Confidential NCU PCB Circuit Diagram China Asia Gulf ...
Page 322: ...6 10 Confidential 2 WIRING DIAGRAM Wiring diagram ...
Page 323: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 324: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL REPLACEMENT PARTS 7 1 ...
Page 326: ...APPENDIX 1 SERIAL NUMBERING SYSTEM Confidential ...
Page 330: ...APPENDIX 3 INSTALLING THE MAINTENANCE DRIVER Confidential ...
Page 334: ...App 3 4 Confidential 10 Alert warning message appears click Continue Anyway to proceed ...
Page 336: ...APPENDIX 4 HOW TO MAKE PROTECTIVE MATERIAL OF DRUM UNIT Confidential ...