![Brother DCP 7065DN Service Manual Download Page 59](http://html.mh-extra.com/html/brother/dcp-7065dn/dcp-7065dn_service-manual_53128059.webp)
2-22
Confidential
3.3
Communications Error Code
*1 Available in German models only.
Code 1 Code 2
Cause
Refer to:
10
08
Wrong number called.
11
01
No dial tone detected before start of dialing.
11
02
Busy tone detected before dialing.
11
03
2nd dial tone not detected.
11
05
No loop current detected.
*1
11
06
Busy tone detected after dialing or called.
11
07
No response from the remote station in sending.
11
10
Unobtainable tone detected after dialing.
17
07
No response from the calling station in receiving.
20
01
Unable to detect a flag field.
20
02
Carrier was OFF for 200 ms or longer.
20
03
Abort detected (“1” in succession for 7 bits or more).
20
04
Overrun detected.
20
05
A frame for 3 seconds or more received.
20
06
CRC error in answerback.
20
07
Echo command received.
20
08
Invalid command received.
20
09
Command ignored once for document setting or for dumping-
out at turn-around transmission.
20
0A
T5 time-out error
20
0B
CRP received.
20
0C
EOR and NULL received.
32
01
Remote terminal only with V.29 capability in 2,400 or 4,800 bps
transmission.
32
02
Remote terminal not ready for polling.
32
10
Remote terminal not equipped with password function or its
password switch OFF.
32
11
Remote terminal not equipped with or not ready for
confidential mailbox function.
32
12
Remote terminal not equipped with or not ready for relay
broadcasting function.
32
13
No confidential mail in the remote terminal.
Summary of Contents for DCP 7065DN
Page 21: ...CHAPTER 1 SPECIFICATIONS ...
Page 35: ...CHAPTER 2 ERROR INDICATION AND TROUBLESHOOTING ...
Page 44: ...2 7 Confidential ADF part Fig 2 5 Left Side Right Side Document feed path Face up ...
Page 142: ...CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 157: ...3 13 Confidential 4 New toner sensor PCB ASSY New toner sensor PCB ASSY Main PCB ASSY Guide ...
Page 169: ...3 25 Confidential 21 Hook switch PCB Guide Main PCB ASSY Hook switch PCB Side cover L ...
Page 252: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 264: ...CHAPTER 5 SERVICE FUNCTIONS ...
Page 271: ...5 5 Confidential Black and white scanning Fig 5 1 ...
Page 311: ...Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Page 313: ...6 1 Confidential 1 CIRCUIT DIAGRAMS High Voltage Power Supply PCB Circuit Diagram MURATA ...
Page 314: ...6 2 Confidential High Voltage Power Supply PCB Circuit Diagram Panasonic ...
Page 315: ...6 3 Confidential Low Voltage Power Supply PCB Circuit Diagram 115V EDPS 62AF A Delta ...
Page 316: ...6 4 Confidential Low Voltage Power Supply PCB Circuit Diagram 115V MPW3058 MURATA ...
Page 317: ...6 5 Confidential Low Voltage Power Supply PCB Circuit Diagram 230V EDPS 62BF A Delta ...
Page 318: ...6 6 Confidential Low Voltage Power Supply PCB Circuit Diagram 230V MPW3059 MURATA ...
Page 319: ...6 7 Confidential NCU PCB Circuit Diagram U S A Canada ...
Page 320: ...6 8 Confidential NCU PCB Circuit Diagram Europe Oceania ...
Page 321: ...6 9 Confidential NCU PCB Circuit Diagram China Asia Gulf ...
Page 322: ...6 10 Confidential 2 WIRING DIAGRAM Wiring diagram ...
Page 323: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 324: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL REPLACEMENT PARTS 7 1 ...
Page 326: ...APPENDIX 1 SERIAL NUMBERING SYSTEM Confidential ...
Page 330: ...APPENDIX 3 INSTALLING THE MAINTENANCE DRIVER Confidential ...
Page 334: ...App 3 4 Confidential 10 Alert warning message appears click Continue Anyway to proceed ...
Page 336: ...APPENDIX 4 HOW TO MAKE PROTECTIVE MATERIAL OF DRUM UNIT Confidential ...