40
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
53-1002373-02
Router modules
1
Power supply requirements for
BR-MLX-1GFx24-X and BR-MLX-1GFx24-X-ML
interface modules
Table 18
lists the power supply requirements for each type of router when installing 24-port 1 Gbps
fiber interface modules.
20-port 100/1000 Ethernet interface module
Figure 23
shows the front panel of the 20-port 100/1000 Gbps Ethernet SFP interface module.
FIGURE 23
20-port 100/1000 Ethernet module front panel
TABLE 18
Power supply requirements for 24-port 1 Gbps fiber interface module
Router type
Number of 24-port 1
Gbps fiber interface
module installed
Power supply requirements
MLXe-4
three
one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
four
two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
MLX-4 and
Brocade NetIron
XMR 4000
four
one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
MLXe-8
seven
two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
eight
three 1200W PSU
for 3+1 redundancy, install four 1200W PSU
Brocade NetIron
XMR 8000
eight
two 1200W PSU
for 2+2 redundancy, install eight 1200W PSU
All 16-slot routers sixteen
four 1200W PSU
for 4+4 redundancy, install eight 1200W PSU
All 32-slot routers thirty-two
four 2400W PSU
for 4+4 redundancy, install eight 2400W PSU