Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
123
53-1002373-02
Installing a Brocade MLXe-32 router
2
(OSP) or its wiring. These interfaces are designed for use as intra-building interfaces only (Type 2
or Type 4 ports as described in GR-1089-CORE, Issue 5) and require isolation from the exposed
OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect
these interfaces metallically to OSP wiring.
The sequence for installing management, interface, and switch fabric modules is important to
ensure proper fit in the Brocade MLXe-32 router. When populating the router, start with the middle
slot, and work towards the edge. Always fill the bottom slots of the upper and lower card cage of the
router first. Refer to
Figure 8
on page 12 for slot locations.
During the initial installation of modules, it is recommended that you insert all the modules into the
appropriate router slots before tightening the module screws.
For information about how to disable and re-enable power to interface modules, refer to
“Disabling
and re-enabling power to interface modules”
on page 321
When populating the 32-slot router, the modules must be installed in the appropriate slots:
•
Management modules: management slots 1 and 2
•
Switch fabric modules: switch fabric slots 1-8
•
Interface modules: Interface slots 1-32
Refer to
Figure 12
for the locations of these slots.
NOTE
Brocade MLXe modules are dedicated, which means that you must install them in the Brocade MLXe
routers only. If you install a Brocade MLXe module in another Brocade router or a module intended
for another Brocade router in the Brocade MLXe router, the router and module will not function
properly.
Although management modules are designed to be hot-swappable, you must upgrade the software
on all interface modules and management modules to the appropriate software release before
installing them. For more information on the appropriate software release, refer to the Hardware
Installation Notes that shipped with the management module.
If you are installing a redundant management module, refer to the chapter titled
Using a Redundant
Management Module
in the
Brocade MLX Series and Brocade NetIron Family Configuration Guide
for information about how the redundant module works, optional software configurations that you
can perform, and how to manage the redundancy feature.
Before installing modules in the Brocade MLXe-32 router, have the following items available:
•
A large flat-head screwdriver.
•
An ESD wrist strap with a plug for connection to the ESD connector on the router.
DANGER
For safety reasons, the ESD wrist strap should contain a 1 megohm series resistor.