Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
31
53-1002373-02
Router modules
1
Power supply requirements for Gen-1 2-port or 4-port 10 Gbps Ethernet interface modules
Table 10
lists the power supply requirements for each type of router when installing Gen-1 2-port or
4-port 10 Gbps Ethernet interface modules.
TABLE 10
Power supply requirements for Gen-1 2-port or 4-port 10 Gbps Ethernet interface modules
Router type
Number of Gen-1
2-port or 4-port Gbps
Ethernet interface
modules installed
Power supply requirements
MLXe-4
three
one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
four
two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
MLX-4 and
Brocade NetIron
XMR 4000
four
one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
MLXe-8
seven
two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
eight
three 1200W PSU
for 3+1 redundancy, install four 1200W PSU
Brocade NetIron
XMR 8000
eight
two 1200W PSU
for 2+2 redundancy, install eight 1200W PSU
All 16-slot routers sixteen
four 1200W PSU
for 4+4 redundancy, install eight 1200W PSU
All 32-slot routers thirty-two
four 2400W PSU
for 4+4 redundancy, install eight 2400W PSU