Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
33
53-1002373-02
Router modules
1
For an up to date list of the 10 Gbps XFP-compliant fiber-optic transceivers that are available from
Brocade, refer to the latest version of the Brocade Optics Family Data Sheet, available online in the
following location:
http://www.brocade.com/downloads/documents/data_sheets/product_data_sheets/Optics_DS.p
df
For more information about fiber-optic transceivers and associated cabling, refer to
“Installing a
fiber-optic transceiver”
on page 318.
Power supply requirements for 10Gx4 interface modules
Table 12
lists the power supply requirements for each type of router when installing
BR-MLX-10GX4-X interface modules.
TABLE 12
Power supply requirements for BR-MLX-10GX4-X and BR-MLX-10Gx4-X-ML interface modules
Router type
Number of Gen-2
10GX4-X interface
modules installed
Power supply requirements
MLXe-4
three
one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
four
two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
MLX-4 and
Brocade NetIron
XMR 4000
four
one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
MLXe-8
seven
two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
eight
three 1200W PSU
for 3+1 redundancy, install four 1200W PSU
Brocade NetIron
XMR 8000
eight
two 1200W PSU
for 2+2 redundancy, install eight 1200W PSU
All 16-slot routers sixteen
four 1200W PSU
for 4+4 redundancy, install eight 1200W PSU
All 32-slot routers thirty-two
four 2400W PSU
for 4+4 redundancy, install eight 2400W PSU