![Brocade Communications Systems ICX 7250 Stacking Deployment Manual Download Page 14](http://html1.mh-extra.com/html/brocade-communications-systems/icx-7250-stacking/icx-7250-stacking_deployment-manual_2817204014.webp)
Optics information for the Brocade ICX7450 stacking (Continued)
TABLE 3
QSFP Hardware
Description
BRCD Part Number
40G-QSFP-LR4
40GE LR
57-1000263-01
40G-QSFP-LR4
40GE LR
57-1000263-01
40G-QSFP-C-00501
40GE QSFP to QSFP 0.5M
Cable(Passive)
58-0000056-01
40G-QSFP-C-00501
40GE QSFP to QSFP 0.5M
Cable(Passive)
58-0000056-01
40G-QSFP-C-00501
40GE QSFP to QSFP 0.5M
Cable(Passive)
58-0000056-01
40G-QSFP-C-0101
40GE QSFP to QSFP 1M
Cable(Passive)
58-0000033-01
40G-QSFP-C-0101
40GE QSFP to QSFP 1M
Cable(Passive)
58-0000033-01
40G-QSFP-QSFP-C-0101
40GE QSFP Active Copper 1m
58-0000041-01
40G-QSFP-QSFP-C-0101
40GE QSFP Active Copper 1m
58-0000041-01
40G-QSFP-QSFP-C-0301
40GE QSFP Active Copper 3m
58-0000042-01
40G-QSFP-QSFP-C-0301
40GE QSFP Active Copper 3m
58-0000042-01
40G-QSFP-QSFP-C-0501
40GE QSFP Active Copper 5m
58-0000043-01
40G-QSFP-QSFP-C-0501
40GE QSFP Active Copper 5m
58-0000043-01
Stack construction method 1: Stack secure setup
Description
'Stack secure setup' utility is the most convenient of all methods to form a stack. This utility uses a
Brocade proprietary discovery protocol that discovers units that are connected upstream and
downstream from the switch where this command is entered, the intended Active controller.
Steps
Stack formation with secure setup utility:
• Configure 'stack enable' on the intended active controller unit at configuration level.
• Enter 'stack secure setup' on the intended active controller unit at device level.
Detailed steps:
1. Select a unit that you want to become an active controller. Configure 'stack enable' at configuration
level as seen in the following logs.
ICX7450-24 Router#configure terminal
ICX7450-24 Router(config)#
stack enable
Enable stacking. This unit actively participates in stacking
stacking is enable. optical monitoring for stacking ports 1/3/1, 1/4/1 is not
available.
ICX7450-24 Router(config)#
2. Once stack enable is configured, this command will configure two default stack ports, 1/3/1 and
1/4/1 as seen in the message displayed. This can be confirmed using 'show run' command.
ICX7450-24 Switch(config)#show running
Current configuration:
!
ver 08.0.20T213
Stack construction method 1: Stack secure setup
14
Brocade ICX 7450, Brocade ICX 7750, and Brocade ICX 7250 Stacking Deployment Guide
53-1003581-03