![Brocade Communications Systems Fabric OS v7.0.2 Release Note Download Page 95](http://html1.mh-extra.com/html/brocade-communications-systems/fabric-os-v7-0-2/fabric-os-v7-0-2_release-note_2817373095.webp)
Fabric OS v7.0.1b Release Notes v1.0
Page 95 of 99
Closed with Code Change in Fabric OS v7.0.0a – GA June 2, 2011
This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of
June 2, 2011 in Fabric OS v7.0.0a.
Defect ID:
DEFECT000321855
Technical Severity:
High
Summary:
CRC and/or CDR-5021 errors seen on DCX, DCX-4S, or 5100 switch platforms
Symptom:
CRC or other errors as described below: 1. Port 7/0 detected CRC error with good EOF
when FC8-16 is placed in DCX-4s Slot7. For the solution to be effective, one must execute:
serdestunemode --set; 2. Port 7/0, 7/10 detected CRC error when FX8-24 is placed in DCX-
4s slot7. May also see CRC error on corresponding core blade backend port 3/10 6/30.
Solution is effective upon upgrade, hafailover or re-init of blade. 3. 5100 experience CRC
error with 3rd party tape device. 4. FC10-6 in DCX detects backend port with stuck VC after
link level error (CDR-5021)
Feature:
FC10-6 Platform Services
Function:
ASIC Driver
Probability:
Low
Found in Release:
FOS6.3.1
Service Request ID:
451697
Where Else Fixed:
FOS7.0.0 GA
Defect ID:
DEFECT000345259
Technical Severity:
High
Summary:
FC8-64 blade set to FAULTY 51 after removal/insertion of that blade in DCX 8510 chassis
with diagpost on
Symptom:
May see a faulted blade upon insertion due to diagnostics failure.
Feature:
16G Platform Services
Function:
FOS Kernel Drivers
Probability:
Medium
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000345858
Technical Severity:
High
Summary:
FIPS firmware integrity check has gaps in coverage
Symptom:
None
Feature:
FOS-Infrastructure
Function:
Firmware Download
Probability:
Low
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000346532
Technical Severity:
High
Summary:
Disable or shutdown BES causes the SVC nodes to go offline and service mode.
Symptom:
Disable or poweroff BES switch causes the SVC nodes to go offline. The SVC nodes reboot
several times before it toggled between offline and services mode.
Workaround:
Issue affects SVC storage with BES going offline. Restart storage with VI/VT members
(BES) online.
Feature:
FC Services
Function:
Name Server
Probability:
High
Found in Release:
FOS7.0.0