Close with Code Change in Fabric OS v7.0.1a
Fabric OS v7.0.2 Release Notes v1.0
Page 60 of 99
Defect ID:
DEFECT000369660
Technical Severity:
Medium
Summary:
Enhanced SERDES tuning to address CRC with good EOF
Symptom:
CRC with good EOF reported with following platform, blade, port combination.
On DCX, when FC8-48 in slot 3, 3/55<->5/18
On DCX-4s, When FC8-48 in slot2, 3/56 <->2/40
On DCX, with FC8-64 in slot12, 5/151<->12/33
On DCX-4S, with FC8-16 in slot1, slot2
On DCX, with FC8-64 in slot2, 8/80 <->2/155
Feature:
Field Escalation
Function:
ASIC Driver
Probability:
Medium
Found in Release:
FOS6.4.2
Service Request ID:
663795
Defect ID:
DEFECT000378374
Technical Severity:
Medium
Summary:
F_Port trunk area configuration may be lost in switches when upgrading to FOS 6.4.x
Symptom:
If there were F_Port trunk configured during switch running at FOS v6.1, Then selected
F_Port trunk configuration performed when FOS v6.2.x/v6.3.x was installed may be lost
after an upgrade from FOS v6.2.x/v6.3.x to FOS v6.4.x.
Feature:
Field Escalation
Function:
Fabric Services
Probability:
Low
Found in Release:
FOS6.4.2
Service Request ID:
689353
Defect ID:
DEFECT000380162
Technical Severity:
Medium
Summary:
F-Port trunk lost connectivity after hafailover
Symptom:
When a hafailover occurs on a fabric switch with F-port trunks, the fabric ID is not updated
on the slave ports of the F-port trunks. This causes the slave ports to have a possibly
incorrect fabric ID. If the entire F-port trunk goes down and a previous slave port becomes
the trunk master of the F-port trunk, this incorrect fabric ID is used and cause ACL check to
fail and frame cannot go through.
Feature:
Field Escalation
Function:
Access Gateway
Probability:
Low
Found in Release:
FOS6.4.2
Service Request ID:
691443
Defect ID:
DEFECT000381085
Technical Severity:
Medium
Summary:
Link timeouts observed on internal port when perform slotpoweroff/on test on multiple
port blades
Symptom:
Timing issue when the blade goes down but the credit loss poll routine detection happens
at same time, trigger raslog C3-1012 and C3-1014:
Feature:
OS Services
Function:
Other
Probability:
Low
Found in Release:
FOS7.0.1