Closed with Code Change in Fabric OS v7.0.0b
Fabric OS v7.0.2 Release Notes v1.0
Page 91 of 99
Defect ID:
DEFECT000354560
Technical Severity:
Medium
Summary:
Failed tape jobs encountered with tape pipelining enabled when utilizing a FICON to ESCON
converter
Symptom:
Tape jobs intermittently fail with tape pipelining enabled when utilizing a FICON to ESCON
converter.
Workaround:
Disable tape pipelining
Feature:
Field Escalation
Function:
FCIP
Probability:
Medium
Found in Release:
FOS6.4.2
Where Else Fixed:
FOS6.4.2 a
Defect ID:
DEFECT000354750
Technical Severity:
Medium
Summary:
Unable to access the boot prom on a 5480 when it is installed in a C-7000 chassis
Symptom:
Unable to access the boot prom on a 5480.
Feature:
UNDETERMINED
Function:
UNDER REVIEW
Probability:
Low
Found in Release:
FOS6.3.1
Service Request ID:
589577
Defect ID:
DEFECT000354967
Technical Severity:
Medium
Summary:
WebTools: When attempting to upgrade a switch in IM2/IM3 to FOS v7.0, fail message
should direct user to Interoperability tab to change switch to Brocade Native Fabric Mode
Symptom:
When upgrading a switch in IM2/IM3 to v7.0 via WebTools, the failure message references
the interopmode command, but does not provide WebTools instructions.
Feature:
FC Services
Function:
Other
Probability:
Medium
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000355888
Technical Severity:
Medium
Summary:
D_Port (CLI): Caution message should not mention Brocade Branded SFPs.
Symptom:
Caution message seen when executing D_Port CLI mentions "only Brocade Branded SFPs".
Feature:
FC Services
Function:
D-port
Probability:
High
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000355909
Technical Severity:
Medium
Summary:
perfaddusermonitor/fmconfig not correctly counting SOFf frames
Symptom:
SOFf frame counter is not detecting SOFf frame ingress/egress when filter monitor is
enabled.
Feature:
Field Escalation
Function:
ASIC Driver
Probability:
High
Found in Release:
FOS6.4.2
Service Request ID:
632819