Closed with Code Change Defects in Fabric OS v7.0.1
Fabric OS v7.0.2 Release Notes v1.0
Page 75 of 99
Defect ID:
DEFECT000317392
Technical Severity:
Medium
Summary:
systemverification failing on 7800.
Symptom:
systemverfication test fails
Feature:
Diagnostics
Function:
Other
Probability:
Low
Found in Release:
FOS6.3.1
Where Else Fixed:
FOS7.0.0 GA
Defect ID:
DEFECT000319548
Technical Severity:
Medium
Summary:
ceeportloopbacktest and ceeportledtest does not properly process all parameters on the
Brocade 8000
Symptom:
Customer cannot utilize all options of the CEE port diagnostic tests
Feature:
Diagnostics
Function:
Other
Probability:
High
Found in Release:
FOS6.4.0
Service Request ID:
451771
Where Else Fixed:
FOS7.0.0 GA, FOS6.4.1 b
Defect ID:
DEFECT000335811
Technical Severity:
Medium
Summary:
Brocade 5450 switches crashed when latest version of enclosure management SW was
used.
Symptom:
Brocade 5450 platform may panic if used with newer version of MMB that uses new ISMIC
block which was previously not supported.
Workaround:
Use initial qualified MMB version
Feature:
Field Escalation
Function:
Panic / OOM
Probability:
Low
Found in Release:
FOS6.2.0
Service Request ID:
530085
Where Else Fixed:
FOS6.4.2 a
Defect ID:
DEFECT000336933
Technical Severity:
Medium
Summary:
Switch sends ELP to device after the device sends FLOGI during power-up sequence
Symptom:
When connected to 4G switch, during a specific storage device power-up sequence, host
cannot access target.
Feature:
Field Escalation
Function:
ASIC Driver
Probability:
Low
Found in Release:
FOS6.1.2
Service Request ID:
444823
Where Else Fixed:
FOS6.4.2