Closed with Code Change in Fabric OS v7.0.0c
Fabric OS v7.0.2 Release Notes v1.0
Page 85 of 99
Defect ID:
DEFECT000369430
Technical Severity:
High
Summary:
Host Discovery issue from edge to edge with VE in BB fabric if EX_Ports are on port 0-3 of
an FX8-24 blade in slot 7 of a DCX-4S.
Symptom:
Hosts will not be able to discover targets across the backbone fabric.
Feature:
Striker/Spike Platform Services
Function:
Routing
Probability:
Low
Found in Release:
FOS7.0.1
Defect ID:
DEFECT000369610
Technical Severity:
High
Summary:
Emulated FICON Tape Read Channel Program can grow too large, resulting in FICON
Protocol timeouts and aborts
Symptom:
FICON Abort during tape read emulation
Feature:
FCIP
Function:
FCIP I/O
Probability:
High
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000365735
Technical Severity:
Medium
Summary:
In Extended Fabric sub tab shows the port speed as 0 for ports configured as N16.
Symptom:
Configured N16 port speed is not displayed as N16 in the port speed column in Extended
Fabric sub tab for 16G platforms.
Feature:
Mgmt Embedded - HTTP
Function:
Other
Probability:
Medium
Found in Release:
FOS7.0.1
Defect ID:
DEFECT000367446
Technical Severity:
Medium
Summary:
diagshow displays incorrect speed value for ports on FCOE10-24 blades
Symptom:
diagshow displays the backend 4G ports. customer is expecting to see the front end 10G
ports instead
Feature:
Diagnostics
Function:
Other
Probability:
High
Found in Release:
FOS6.4.1
Service Request ID:
668999
Defect ID:
DEFECT000374366
Technical Severity:
Medium
Summary:
Stuck VC detection is being intermittently delayed
Symptom:
Stuck VC will be detected, however the detection maybe intermittently delayed
Feature:
Bottleneck detection
Function:
Other
Probability:
Low
Found in Release:
FOS7.0.0