![Brocade Communications Systems Fabric OS v7.0.2 Release Note Download Page 59](http://html1.mh-extra.com/html/brocade-communications-systems/fabric-os-v7-0-2/fabric-os-v7-0-2_release-note_2817373059.webp)
Close with Code Change in Fabric OS v7.0.1a
Fabric OS v7.0.2 Release Notes v1.0
Page 59 of 99
Defect ID:
DEFECT000386528
Technical Severity:
High
Summary:
Switch panic upon detect SRAM parity error on 7500 and FR4-18i
Symptom:
Parity error in ASIC is very rare and may be observed after a long up time. This specific
parity error in 7500/FR4-18i SRAM cannot be recovered by software refresh, thus the
attempted refresh generated switch panic.
Workaround:
Slot /switch needs to be power cycled
Feature:
Field Escalation
Function:
ASIC Driver
Probability:
Low
Found in Release:
FOS6.4.2
Service Request ID:
705301,704563
Defect ID:
DEFECT000389967
Technical Severity:
High
Summary:
Switch name server rejects RFT_ID request on NPIV ports
Symptom:
In FOS v7.0 and later, RFT_IDs requests for several NPIV ports are rejected with reason
0x05 (Logical Busy). Host cannot see device if it does not retry the request.
Feature:
Field Escalation
Function:
Fabric Services
Probability:
High
Found in Release:
FOS7.0.0
Service Request ID:
710571
Defect ID:
DEFECT000360650
Technical Severity:
Medium
Summary:
ports that are not connected randomly go into a disabled state after a hafailover.
Symptom:
ports are disabling on hafailovers on high port count directors
Feature:
16G Platform Services
Function:
Other
Probability:
High
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000364382
Technical Severity:
Medium
Summary:
Executing CMSH through telnet or SSH causes switch panic
Symptom:
Telnet or SSH to BR8000, then starting CMSH will cause switch reboot. No problem when
connecting through console, then CMSH.
Workaround:
Telnet/SSH from same subnet or connect from console
Feature:
CEE-MANAGEABILITY
Function:
CONFIGURATION MANAGER INTERFACE
Probability:
High
Found in Release:
FOS6.4.2
Service Request ID:
657425