Closed with Code Change in Fabric OS v7.0.0b – GA August 24, 2011
This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of
August 24, 2011 in Fabric OS v7.0.0b.
Defect ID:
DEFECT000300506
Technical Severity:
High
Summary:
Observed routing problem after switch running in fmsmode (FICON) changed FID
assignment
Symptom:
Connectivity problems in the fabric after changing FID assignment, switch in fabric reported
[RTWR-1002] and [RTWR-1003] RAS log messages.
Workaround:
Reboot or power cycle the affected switch or switches
Feature:
8G ASIC Driver
Function:
C2 ASIC driver
Probability:
Medium
Found in Release:
FOS6.4.0
Where Else Fixed:
FOS6.4.2 a
Defect ID:
DEFECT000341971
Technical Severity:
High
Summary:
Loop attached device loses secondary disk path after port disable/enable
Symptom:
Secondary paths will not appear in the output from disk query commands.
Feature:
8G Platform Services
Function:
Other
Probability:
Medium
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000344506
Technical Severity:
High
Summary:
Port fenced during supportsave
Symptom:
Port without errors are fenced during supportsave
Feature:
FABRIC WATCH
Function:
PORT FENCING
Probability:
High
Found in Release:
FOS6.4.0
Where Else Fixed:
FOS6.4.2 a
Defect ID:
DEFECT000347632
Technical Severity:
High
Summary:
Delays in Name Server observed during FICON CEC IMLs
Symptom:
Invalid Attachment and Name Server Query failures may be observed due to delays in
Name Server processing when programming CAM entries for the ASIC.
Feature:
8G ASIC Driver
Function:
Other
Probability:
Medium
Found in Release:
FOS7.0.0