![Brocade Communications Systems Fabric OS v7.0.2 Release Note Download Page 83](http://html1.mh-extra.com/html/brocade-communications-systems/fabric-os-v7-0-2/fabric-os-v7-0-2_release-note_2817373083.webp)
Fabric OS v7.0.1b Release Notes v1.0
Page 83 of 99
Closed with Code Change in Fabric OS v7.0.0c – GA November 18, 2011
This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of
November 18, 2011 in Fabric OS v7.0.0c
Defect ID:
DEFECT000354348
Technical Severity:
High
Summary:
Not receiving the RAS log Cx-5021 message for front port partial credit loss on an EX-Port
Symptom:
Customer will be unaware if EX_Ports are leaking credit.
Feature:
8G FCR
Function:
FCR Daemon
Probability:
Low
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000364137
Technical Severity:
High
Summary:
FabricWatch Port Class is not monitoring ICL ports. E-Port Class monitors are monitoring
ICL ports.
Symptom:
ICL Ports will not report any threshold warnings and will not be fenced for Port Class
attributes.
Feature:
FABRIC WATCH
Function:
PORT FENCING
Probability:
High
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000364799
Technical Severity:
High
Summary:
After downgrading from v7.0.0 to v6.4.x, a route rebalance or recalculation will cause some
ICL paths to be blocked.
Symptom:
Connectivity between devices lost after route change.
Workaround:
Disable all ICL ports and then enable all ICL ports.
Feature:
UNDETERMINED
Function:
UNDER REVIEW
Probability:
High
Found in Release:
FOS6.4.2
Defect ID:
DEFECT000364945
Technical Severity:
High
Summary:
Unable create 4th tunnel with crossport circuits in chassis with multiple FX8-24 blades.
Symptom:
Unable create more than three tunnels with crossport circuit configuration in a chassis with
multiple FX8-24 blades.
Feature:
FCIP
Function:
Other
Probability:
High
Found in Release:
FOS7.0.0