![Brocade Communications Systems Fabric OS v7.0.2 Release Note Download Page 74](http://html1.mh-extra.com/html/brocade-communications-systems/fabric-os-v7-0-2/fabric-os-v7-0-2_release-note_2817373074.webp)
Closed with Code Change Defects in Fabric OS v7.0.1
Fabric OS v7.0.2 Release Notes v1.0
Page 74 of 99
Defect ID:
DEFECT000369610
Technical Severity:
High
Summary:
Emulated FICON Tape Read Channel Program can grow too large, resulting in FICON
Protocol timeouts and aborts
Symptom:
FICON Abort during tape read emulation
Feature:
FCIP
Function:
FCIP I/O
Probability:
High
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000369703
Technical Severity:
High
Summary:
Host could not Link up on 8G FC port when the port is configured at a fixed speed of 4G or
8G.
Symptom:
When an 8G capable port is configured at fixed speed of 4G or 8G, and remote is
configured as speed auto negotiation, and there is only 1 port connected to the remote,
after switch reboot, or slotpoweroff/slotpoweron, sometime this port cannot sync up.
Portdisable/portenable cannot recover. When there are more than 1 links connected, this
problem is not observed.
Feature:
Field Escalation
Function:
ASIC Driver
Probability:
Low
Found in Release:
FOS6.2.2
Service Request ID:
672599
Defect ID:
DEFECT000370943
Technical Severity:
High
Summary:
Network scanning application causing high CPU utilization by CNM daemon.
Symptom:
Possible module timeouts seen during processing intensive actions such as SupportSave.
Feature:
Data Security
Function:
HA Cluster
Probability:
Low
Found in Release:
FOS6.4.2
Service Request ID:
123606
Defect ID:
DEFECT000373075
Technical Severity:
High
Summary:
Linux kernel bug causing panic on switch running FOS v6.4.2
Symptom:
Kernel panic and reboot of switch
Feature:
Field Escalation
Function:
Panic / OOM
Probability:
Low
Found in Release:
FOS6.4.2
Service Request ID:
680849
Defect ID:
DEFECT000375295
Technical Severity:
High
Summary:
F_Port stuck in Disabled (N-Port Offline for F-Port) after AG reboot
Symptom:
F_Ports on some access gateways are stuck in F_Port Disabled state (N-Port Offline for F-
Port) and observe raslog reports: [AG-1005], FDISC response was dropped.
Feature:
Field Escalation
Function:
Access Gateway
Probability:
Low
Found in Release:
FOS6.2.2
Service Request ID:
684505