Defect ID:
DEFECT000385320
Technical Severity:
Medium
Summary:
FICON Selective resets during sort tape job with large channel programs when running
through FICON to ESCON converter and FCIP FICON Tape Pipelining.
Symptom:
Customer sees the tape application fail with MIH error.
Feature:
FCIP
Function:
FCIP I/O
Probability:
Low
Found in Release:
FOS7.0.1
Defect ID:
DEFECT000386728
Technical Severity:
Medium
Summary:
FICON Printer Emulation enabled encounters DP Panic with 3900 type printers
Symptom:
FCIP Complex DP reset, FCIP Tunnel failure (on the peer side).
Feature:
FCIP
Function:
Emulation
Probability:
High
Found in Release:
FOS7.0.1
Defect ID:
DEFECT000387371
Technical Severity:
Medium
Summary:
Replication application getting errors after upgrading from FOSv6.4.1_fcoe to FOSv7.0.x
with FCIP emulation
Symptom:
Customer will get failures in Teradata replication
Feature:
Field Escalation
Function:
FCIP
Probability:
High
Found in Release:
FOS7.0.0
Service Request ID:
706489
Defect ID:
DEFECT000388672
Technical Severity:
Medium
Summary:
FCIP tunnel bounces on 7800, high emulated IO can cause local keep alive timeout
Symptom:
Customer will get FICON keep alive timeout if there is not enough bandwidth on the FCIP
tunnel.
Feature:
Field Escalation
Function:
FCIP
Probability:
Low
Found in Release:
FOS6.4.1
Service Request ID:
670797