Defect ID:
DEFECT000353445
Technical Severity:
High
Summary:
Out of band bulk requests (SMI) can cause Name Server to panic in frame redirection
environments.
Symptom:
Multiple name server panics observed in conjunction with applications which performs
GXX_ID (such as GCS_ID) queries via out of band.
Workaround:
Avoid GXX_ID (like GCS_ID) queries via out of band (through RPC) querying with ID of
device that is part of frame redirection
Feature:
Field Escalation
Function:
Fabric Services
Probability:
Low
Found in Release:
FOS6.3.1
Service Request ID:
627097
Where Else Fixed:
FOS6.4.2 b GA
Defect ID:
DEFECT000354348
Technical Severity:
High
Summary:
Not receiving the RAS log Cx-5021 message for front port partial credit loss on an EX-Port
Symptom:
Customer will be unaware if EX_Ports are leaking credit.
Feature:
8G FCR
Function:
FCR Daemon
Probability:
Low
Found in Release:
FOS7.0.0
Defect ID:
DEFECT000356094
Technical Severity:
High
Summary:
IDLE not being sent after NOS - results in other issues and eventually causes G_Port.
Symptom:
Customer simply notices that one side the ISL becomes a G_Port, while the peer remains
an E_Port.
Feature:
Field Escalation
Function:
Fabric Services
Probability:
Low
Found in Release:
FOS6.2.2
Service Request ID:
602057
Defect ID:
DEFECT000356468
Technical Severity:
High
Summary:
Access Gateway does not clean up frame exchange properly if FLOGI/FDISC comes in from
different ports together with same exchange ID (OX-ID).
Symptom:
3rd party application reports migration failure between servers.
Feature:
Field Escalation
Function:
Access Gateway
Probability:
Low
Found in Release:
FOS6.3.2
Service Request ID:
629273
Where Else Fixed:
FOS6.4.2 b GA