Defect ID:
DEFECT000387371
Technical Severity:
Medium
Summary:
Replication application getting errors after upgrading from FOSv6.4.1_fcoe to FOSv7.0.x with FCIP
emulation
Symptom:
Customer will get failures in Teradata replication
Risk of Fix:
Low
Feature:
FOS Software
Probability:
High
Function:
FCIP
Reported In Release:
FOS7.0.0
Service Request ID:
706489
Defect ID:
DEFECT000387536
Technical Severity:
Medium
Summary:
Perfttmon only seems to output ingress values when egress is chosen
Symptom:
In NPIV setup, unable to get valid data for running perfttmon.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
High
Function:
ASIC Driver
Reported In Release:
FOS7.0.1
Service Request ID:
693225
Defect ID:
DEFECT000387601
Technical Severity:
Medium
Summary:
Embedded platform with internal CU port turned into G Port
Symptom:
Server lost access to the devices when internal CU port connected to HBA turned into G_Port.
Risk of Fix:
Medium
Feature:
8G ASIC Driver
Probability:
Medium
Function:
ASIC Driver
Reported In Release:
FOS7.0.1
Defect ID:
DEFECT000388283
Technical Severity:
Medium
Summary:
zoned caused switch panic
Symptom:
During rename zone, add new zone name in list and then remove the old zone name, switch panic.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Fabric Services
Reported In Release:
FOS6.3.2
Defect ID:
DEFECT000388672
Technical Severity:
Medium
Summary:
FCIP tunnel bounces on 7800, high emulated IO can cause local keep alive timeout
Symptom:
Customer will get FICON keep alive timeout if there is not enough bandwidth on the FCIP tunnel.
Risk of Fix:
Medium
Feature:
FOS Software
Probability:
Low
Function:
FCIP
Reported In Release:
FOS6.4.1
Service Request ID:
670797
Defect ID:
DEFECT000388762
Technical Severity:
High
Summary:
Switch upgrade from FOS 6.3.x to 6.4.x in IM2/IM3 mode caused zone daemon memory space over
run.
Symptom:
Zoned panic after upgrade, when a remote domain goes out of fabric.
Workaround:
To avoid this problem the customer can just do a hafailover when the firmware is
completely upgraded.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Fabric Services
Reported In Release:
FOS6.4.1
Service Request ID:
709913