100
IX.
IX.
Wiring Diagrams/Tech Sheet
Wiring Diagrams/Tech Sheet
Measuring SHV99, SHX99, SHY99 Resistances @ Modules
Measuring SHV99, SHX99, SHY99 Resistances @ Modules
Control Module – I2
I2.
1
2
3 4 5 6
.5-
.6-
3
4
5
6
1 2
.4-
.2-
1
2
3
1
2
1
2 3
4 5
To
display
module
.7-
.8-
.9-
1
2
3 4 5
1
2
.13-
.3
3
4
1
2
3
4
1
2
.1-
5 6
.10-
3
1 2
4
Measure
NTC
(~ 55k
Ω
@ 72ºF)
To Aqua
Sensor
To water
level
switch
To water
switch
Measure circulation motor
(~ 7
Ω
) – door must be closed
To hot line
To on/off switch (
resets module
)
To dispenser actuator
Measure drain
motor (~ 16.5
Ω
)
To water
fill valve
To neutral
To heater, Hi-Limit
& flow switch
Hot line to water switch & float switch
RD
RD
BU
BU
YE
BK
BK
GY
BK
WH
RD
GY
GY
BK
WH
YE
WH
WH
RD
Wire color codes:
BK = Black
BN = Brown
BU = Blue
GY = Gray
RD = Red
WH = White
YE = Yellow
HINT:
Water valve and drain
motor can be measured from front
of dishwasher. Resistances are:
•
Water valve ~ 1 k
•
Drain motor ~ 16.5
NOTE:
These use the
top-load dispenser with
different actuator &
rinse-aid sensor.
NOTE:
Control modules for SHV/SHX/SHY99
models are mounted on bases where base wiring
harnesses are mounted for other models. Control
modules are accessed through the right side after
pulling dishwashers out, so resistances cannot be
measured from the front.