35
VI.
VI.
Component Access/Replacement
Component Access/Replacement
Circulation Pumps
Circulation Pumps
-
-
Access (3)
Access (3)
To raise right side of tank for circulation pump access
To raise right side of tank for circulation pump access
:
:
Remove one T-20 Torx screw from both rear corners holding tank to base
(1)
-- removing screw from both sides allows tank to be blocked upward.
Remove right toe kick bracket by removing T-20 Torx screw
(2)
.
Remove T-20 Torx screws from front right bottom corner holding tank to
base
(3)
.
Remove right hinge cover
(4a)
, release right door tension cord from hinge
(4b)
& remove ground wire
(4c)
.
Raise and block up tank as shown with strut onto base
(5a)
, sliding a piece
of wood or other solid material between the tank and base to keep tank
from falling back onto base
(5b)
.
1
2
Screw
3
4c
4a
4b
5b
5a
CAUTION:
Its not recommended to turn dishwashers upside-down for tank access. When
dishwashers are turned upside-down, water can flow into the diaphragm of the water fill
assembly and cause water to not fill properly.