37
VI.
VI.
Component Access/Replacement
Component Access/Replacement
Circulation Pumps
Circulation Pumps
-
-
Reassembly
Reassembly
To remove & install impeller (using kit # 167085)
To remove & install impeller (using kit # 167085)
:
:
While holding motor fan so shaft won’t spin
(1a)
, unscrew impeller
counterclockwise
(1b)
.
Rotate pump housing counterclockwise until tabs clear, then lift
housing from motor
(2)
.
Remove spring and O-ring from pump housing, then lift spacer up
from motor shaft
(3)
.
Place replacement spacer onto motor shaft
(4)
. Note larger end
goes onto shaft 1st.
Install replacement spring & O-ring onto pump housing, then line up
housing-motor tabs to screw pump housing onto motor
(5a)
. Screw
replacement impeller onto motor shaft
(5b)
.
Align motor to pump housing with capacitor @ 11:00 position to
facilitate reassembly.
1b
Motor fan
1a
3
4
2
5a
5b