76
VIII.
VIII.
Troubleshooting
Troubleshooting
Circulation Pump
Circulation Pump
–
–
Replacing Impellers (2)
Replacing Impellers (2)
Occasionally, a circulation pump will jam when debris gets caught inside
(when the sump filter wasn’t tightened down) or when a dishwasher hasn’t
been used for months. Often circulation pumps are replaced when merely
changing the
impeller
(kit #
167085
,
item # 24
) will solve the problem.
“Softer bearing” circulation pump
supported by rubber straps
impeller
spacer
Impeller
Sump
8mm nutdriver
Sump
access to
impeller
impeller
spacer
“Old” style circulation pump
supported by rubber bushings
CAUTION:
When replacing an
impeller, install the black spacer
between the pump motor and the
rear pump housing.
Failure to do so
may lock up the pump and
damage the rear pump housing!
HINT:
When
replacing an
impeller, instruct the
customer to tighten
the sump filter
properly to avoid
future problems.
sump
microfilter