
80
VIII.
VIII.
Troubleshooting
Troubleshooting
Circulation Pump
Circulation Pump
–
–
Pump & Motor Part # Changes
Pump & Motor Part # Changes
HINT:
The preferred repair for
replacing pump impellers is the #
167085
impeller kit. The other
solution is using complete pump
assembly #
239144
. The #
266511
pump motor only should only be used if
the motor fails (which rarely happens).
NOTE:
The #
167085
impeller kit
and #
263835
index UC/06
circulation pump motor only part #’s
have not changed and still are used.
NOTE:
The circulation pump
assembly part # has been changed
from #
266511
to #
239144
.
Please check all pumps ordered or
already in stock to make sure they
show part #
239144
.
#
167085
impeller kit
#
167235
capacitor
#
266511
motor only
#
239144
complete pump
assembly
#
266514
front pump housing
#
267739
rear pump
housing
#
171598
sump-pump gasket
The softer bearing (UC/07, UC/11 & UC/12 index) circulation pump and motor
only part #’s for all
B
&
G
models have been changed to make
parts ordering more consistent throughout the world. All
B
&
G
parts in stock have been changed to these new part #’s as follows:
•
239144
-- complete circulation
pump assembly (with impeller) for
all
B
&
G
dishwasher models with softer
bearing (all models with index #’s
UC/07, UC/11 & UC/12)
•
266511
-- circulation pump motor
only for all
B
&
G
dishwasher models with softer
bearing (all models with index #’s
UC/07, UC/11 & UC/12)