Storage time for cables and con‐
nectors
Storage time
Measures prior to commissioning
< 1 year
None
1 ... 5 years
⇒Check the electric contacts to verify that they are free from
corrosion
> 5 years
⇒If the cable or the cable jacket has porous parts, replace it;
otherwise check the electric contacts to verify that they are
free from corrosion
Tab. 11-6:
Measures before commissioning of cables and connectors that have
been stored over longer periods of time
308/409
Handling and transport
MBT High Synchronous Torque Motors
Bosch Rexroth AG R911298798_Edition 08