Fig. 12-12:
Parallel motor arrangement (cable outlet in the same direction)
Connection in case of arrangement with cable outlet in the same direction
Drive controller
(slot designation at X5)
A1
A2
A3
Stator 1
1 (U)
2 (V)
3 (W)
Stator 2
1 (U)
2 (V)
3 (W)
Tab. 12-4:
Connecting the power wires in case of parallel arrangement of sta‐
tors with equal cable outlet direction on a drive controller
Parallel arrangement - power ca‐
ble connection (cable outlet in op‐
posite directions)
If the stator is mounted with cable outlet in opposite directions, two phases
must be rotated and applied according to
.
Fig. 12-13:
Parallel motor arrangement (cable outlet in opposite directions)
Connection in case of stator arrangement with cable outlet
in opposite directions
Drive controller
(slot designation at X5)
A1
A2
A3
Stator 1
1 (U)
2 (V)
3 (W)
Stator 2
1 (U)
3 (W)
2 (V)
Tab. 12-5:
Connection of the power wires in case of parallel arrangement of pri‐
mary parts on a drive controller
MBT High Synchronous Torque Motors
327/409
Installation
R911298798_Edition 08 Bosch Rexroth AG
Summary of Contents for rexroth MBT
Page 1: ...MBT High Synchronous Torque Motors Project Planning Manual R911298798 Edition 08 ...
Page 18: ...6 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Page 32: ...20 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Page 240: ...228 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Page 298: ...286 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Page 416: ...404 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Page 421: ...Notes MBT High Synchronous Torque Motors 409 409 ...