EN
| 50
Bosch Security Systems | 02 April 2004
LTC 8850 |
Instruction Manual
|
Allegiant Server
Parameter Miscellaneous Table
This table affects the time and date display that
appears on the monitors connected to the Allegiant.
There are three possible ways to display the date in a
double digit numerical format: month/day/year
(MM/DD/YY); day/month/year (DD/MM/YY); and
year/month/day (YY/MM/DD).
The time format can display either civilian (12 hour) or
military time (24 hour).
The broadcast duration is used to determine the
amount of time a broadcast message is displayed on
the Allegiant monitors. See
Allegiant Server Menus
Online Broadcast
SECTION.
Figure 89 Parameter Miscellaneous Table
Parameter Options Table
The following section covers the Miscellaneous
Configuration Parameters.
NOTE: Certain options would not be displayed if they
do not apply to the Allegiant model being programmed.
Figure 90 Parameter Options Table
Enable Keyboard Password Log-in
When Enable Keyboard Password Log-in is checked,
all users will be required to enter a user number and
the correct password before interaction with the system
is permitted. When Enable Keyboard Password Log-in
is not checked, no user log-in is required.
This option is overridden when the Allegiant CPU
DIP switch S101 (S1002 on LTC 8500 systems) switch
5 is in the OFF position. In this case, no user log-in is
required, regardless of the state of this checkbox.
Systems where the CPU DIP switches are not easily
accessible, such as LTC 8100, LTC 8200, LTC 8300,
and LTC 8900, are shipped with the switch ON, and
the log-on/log-off features are controlled by this
option. As long as CPU DIP switch 5 is ON, this
function can also be selected using a system Keyboard
User Function 27.
Enable Console Password Log-in
When Enable Console Password Log-in is checked, all
users will be required to enter a user number and the
correct password before interaction with the system is
permitted. When Enable Console Password Log-in is
not checked, no user log-in is required.
This option is overridden when the Allegiant CPU
DIP switch S101 (S1002 on LTC 8500 systems) switch
5 is in the OFF position. In this case, no user log-in is
required, regardless of the state of this checkbox.
Systems where the CPU DIP switches are not easily
accessible, such as LTC 8100, LTC 8200, LTC 8300,
and LTC 8900, are shipped with DIP switch 5 ON,
and the log-on/log-off features are controlled by this
option. As long as CPU DIP switch 5 is ON, this
function can also be selected using a system Keyboard
User Function 28.
Priority 1 Users Allowed Multiple Log-ins
When this option is checked the System Administrator
(priority level 1 user) may be logged on to more than
one Allegiant keyboard at a time. When this option is
not checked, the System Administrator will
automatically be logged off of the previous keyboard
when he logs onto a new keyboard. All other priority
level users are always limited to using only one
keyboard at a time.