EN
| 22
Bosch Security Systems | November 17, 2004
DÉSA
XL
|
Instruction Manual
|
System Setup Options
8.3.4 External Monitor
This screen is used to select cameras to be displayed on the analog monitor
output.
8.3.4.1
Dwell (Sec)
is the time that each selected camera will be
displayed during sequence operation. Cameras are available
only if
Enabled
in
Camera Setup
.
Synchronize External Monitor
: Once cameras have been added and
saved, press this button to reset the sequencing.
8.3.5 PTZ Camera Alarm/Preset Setup
8.3.5.1
This option can only be used if there is a camera with
PTZ
selected in
Camera Setup
.
8.3.5.2
Press
Alarm/Preset
to display the
Setup
screen.
8.3.5.3
Cameras with
PTZ
selected appear on the
left side of the chart, and across the top are
the sensors (alarm inputs).
8.3.5.4
Click the box intersecting the desired
camera with the appropriate alarm. A
dropdown box with 1-10 presets will appear.
Select the preset to be associated with that
alarm input.
8.3.5.5
The same preset can be assigned to as many
of the cameras or alarm inputs as desired.