EN
| 21
Bosch Security Systems | November 17, 2004
DÉSA
XL
|
Instruction Manual
|
System Setup Options
8.3.1.5
Motion
associates motion activity to other cameras in the system, to record based on another
camera’s motion. Multiple cameras can be associated to multiple other cameras’ motion.
(Example - 2, 3, 4).
8.3.1.6
PTZ
: If checked, designates that the camera connected is a PTZ type camera.
8.3.1.7
Type
: If the
PTZ
box has been checked for any camera, the type of PTZ protocol to be used can be
selected. The default is
Bosch biphase protocol
. NOTE: Biphase and Pelco
®
protocols have been tested
and verified. All other protocols have yet to be tested.
8.3.1.8
The scroll bar on the right side of the display allows scrolling up or down to reveal additional
cameras.
8.3.2 Sensor (Alarm) Setup
8.3.2.1
Enable (Disable)
: If checked, enables an
alarm input; remove the check to disable
the alarm input.
8.3.2.2
NC/NO
: Press
NC/NO
to toggle between
normally closed or normally open alarm
input.
8.3.2.3
Sound File
: Any .wav file can be loaded into
the Wave folder in the following directory:
C:\DESA\Wav. This .wav file provides audible
indication that an alarm input has been
triggered (example - greeting.wav).
8.3.2.4
Recording Time By Sensor, Motion
sets 1 to 60
seconds of global post-alarm recording once
an alarm has been triggered.
8.3.3 Control Setup
8.3.3.1
Enable (Disable)
activates/deactivates the
designated Control Output.
8.3.3.2
Name
designates a camera description to
be associated with each Control Output.
Length is limited to 13 uppercase
characters or 14 lowercase characters.
8.3.3.3
Auto ON/OFF Time
: Setting an ON and
OFF time of day defines the period of
time (each day) during which the control
is activated.
8.3.3.4
Sensor (Alarm)
associates the physical
sensor inputs to a specific Control
Output. Multiple sensors can be
associated with multiple auxiliaries, by
separating the alarm numbers by
commas i.e. 1,2,3, etc.
8.3.3.5
Dwell
is the duration that the Control will be closed, once triggered by an sensor input. The
maximum is 9999 seconds, individually.