AMAX panel 2000 / AMAX panel 2000 EN
System Functions | en
39
Bosch Sicherheitssysteme GmbH
Installation Manual
F.01U.241.127 | V4 | 2011.12
6
System Functions
6.1
Duress alarm
This function allows code holders to perform a keypad Duress Alarm.
A Keypad Duress Alarm is used as a silent holdup alarm when 0 is added to the end of a valid
Code used to disarm the system.
User
Code
Install
er
Code
Function
Description
•
•
0
#
•
•
1
#
Siren test (Refer to 6.2 )
•
•
2
#
Fault and Tamper analysis (Refer to 6.3 )
•
•
3
#
View date and time (Refer to 6.4 )
•
•
4
#
Walk test (Refer to 6.5 )
•
•
5
#
Event memory recall (Refer to 6.6 )
•
•
6
#
Reset panel/clear siren (Refer to 6.7 )
•
•
7
#
Initiate a modem call (Refer to 6.8 )
•
•
8
#
Send Test report (Refer to 6.9 )
•
•
9
#
Bypass (inhibit) (Refer to 6.10 )
•
•
96
#
Show Zone type (Refer to 6.11 )
•
97
#
Bypass all faults (Refer to 6.12 )
•
98
#
*
Enable=# / Disable=* installer code user's access (Refer to
6.13 )
•
•
99
#
Change individual code (Refer to 6.14 )
•
955
#
Change/View date and time (Refer to 6.15 )
•
956
#
Add/delete a level 2 user (Refer to 6.16 )
•
956
#
Add/delete Remote Radio User Codes (Refer to 6.17 )
•
957
#
Change domestic phone numbers (Refer to 6.18 )
•
958
#
Enter Programming Mode (Refer to 6.19 )
•
959
#
Exits from installer’s programming mode without saving
the programmed data. (Refer to 6.20 )
•
960
#
Exits from installer’s programming mode with saving the
programmed data. (Refer to 6.21 )
•
961
#
Resets the control panel to factory defaults. (Refer to
6.22 )
•
962
#
Copies the control panel memory to the programming key.
(Refer to 6.23 )
•
963
#
Copies the programming key data to the control panel
•
999
#
Displays the software version number or control panel
type. (Refer to 6.25 )
Default Pads on PCB
Default the control panel with the hardware (Refer to
6.26 )