38
en | Fault and Tamper Description
AMAX panel 2000 / AMAX panel 2000 EN
F.01U.241.127 | V4 | 2011.12
Installation Manual
Bosch Sicherheitssysteme GmbH
Zone Tamper Zone Indication
The zone indicator 6 lights to indicate Tamper conditions.
Enter [6] to step to Zone Indicator list to identify the Tamper Zone.
1=Zone 1 2=Zone 2 3=Zone 3 4=Zone 4 5=Zone 5 6=Zone 6 7=Zone 7 8=Zone 8
5.8
External Fault
Condition:
Fault contact (direct connected to the Zone) is triggered (Zone type = External Fault)
Restore:
Fault contact is restored and Fault condition is reset.
Supervise:
1.
Report the Fault condition to configured destination on Location 140 when the Fault
condition is detected.
2.
Slow flash FAULT indicator (refer the detailed description in chapter keypad indicators).
3.
When the Fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
External Fault Zone
The zone indicator 8 lights to indicate External Fault conditions.
Enter [8] to step to Zone Indicator list to identify the zone where the fault input is connected.
1=Zone 1 2=Zone 2 3=Zone 3 4=Zone 4 5=Zone 5 6=Zone 6 7=Zone 7 8=Zone 8