Example:
If the events occurred in the following order:
The alarm memory is played back in this order:
Each event is indicated by a beep and a lit indicator.
Resetting a disarmed 24-Hour alarm is indicated by a beep only.
After the last event, two beeps sound to indicate the end of the playback.
You can stop the replay at anytime by pressing [#].
If the system is armed in STAY mode, the STAY indicator shows the event memory playback.
If the control panel is powered down the memory of all events is saved.
4.6
Reset the Control Panel
This function allows code holders to reset all Alarm Faults and Tamper conditions.
Enter your code and then press [6] [#].
The keypad beeps twice and the signal is eliminated.
4.7
Bypassing
4.7.1
Bypassing Zones
By bypassing Zones, one or more zones are disabled for one arming cycle. After bypassing a
zone, you can arm the system even when a zone is in alarm state.
How to bypass a zone
1.
Enter your code and press [9] [#]. The STAY indicator flashes fast.
2.
Enter the zone number you wish to bypass, then press the [*] key.
(If you wish to bypass multiple zones, please repeat step 2).
3.
If you wish to cancel bypassed zone, enter the zone number of the bypassed zone , then
press the [*] key.
(If you wish to cancel several bypassed zones, please repeat step 3.)
4.
Press [#] to exit.
Sequence
Event
1
System armed in AWAY mode
2
Alarm in Zone 3
3
Alarm in Zone 4
4
System disarmed
Sequence
Indication
Event
1
All indicators off
System disarmed
2
Zone 4 and AWAY indicators light
Alarm in Zone 4
3
Zone 3 and AWAY indicators light
Alarm in Zone 3
4
AWAY indicator lights
System armed in AWAY mode
NOTICE!
You can reset alarms, faults or tamper conditions, only when they are not active anymore.
NOTICE!
If the selected zone is already bypassed, when operating this zone, the bypass from this zone
will be cancelled.